ISO/IEC 15415 standard

The ISO/IEC 15415 standard is primarily used to evaluate QR codes printed on labels.

The QR code is rated based on 8 different parameters. The rating process will evaluate decoding, character contrast, modulation, reflectivity,

The positioning pattern is damaged, axial non-uniformity, mesh non-uniformity, and unused error correction parameters are rated.


XTIOT provides 11 symbologies for Data Matrix ECC 200, QR Code, Micro QR Code or Aztec Code

Rating parameters: 'Overall Quality', 'Contrast', 'Modulation', 'Fixed Pattern Damage', 'Decode', 'Axial Non Uniformity', 'Grid Non-Uniformity', 'Unused Error Correction', 'Reflectance Margin' , 'Print Growth', and

'Contrast Uniformity'.

PDF417 symbology provides 7 rating parameters: 'Overall Quality', 'Start/Stop Pattern', 'Codeword Yield', 'Unused'

Error Correction', 'Modulation', 'Decodability', and 'Defects'.


ISO/IEC TR 29158 (AIM DPM-1-2006) standard

The AIM DPM-1-2006 standard is mainly used to evaluate the quality of QR code marking for direct part marking.

The quality parameters and rating process for DPM codes are similar to the ISO 15415 standard, but there are some important differences.

▪ Global threshold calculation.

▪ Modulation calculations.

▪ In addition to 45° illumination, the AIM DPM standard allows 30°, 90° and dome illumination.

Halcon DPM codes for Data Matrix ECC 200, QR Code, Micro QR Code or Aztec Code

12 parameters are provided: 'Overall Quality', 'Cell Contrast', 'Cell Modulation', 'Fixed Pattern Damage', 'Decode',

'Axial Non-Uniformity', 'Grid Non-Uniformity', 'Unused Error Correction', 'Mean Light', 'Reflectance Margin',

'Print Growth', and 'Contrast Uniformity'.

Parameters 'Cell Contrast', 'Cell Modulation' of AIM DPM-1-2006 and ISO/IEC 15415:2011

The parameters 'Contrast', 'Modulation' are the same, but there is one more parameter 'Mean Light'.



SEMI T10-0701 Standard

  The SEMI T10-0701 standard is primarily used to evaluate the imprinting quality of DataMatrix codes imprinted on semiconductor-related materials.

  Halcon provides 21 rating parameters for Data Matrix ECC 200 symbology: 'P1 Row', 'P1 Column', 'P2 Row',

'P2 Column', 'P3 Row', 'P3 Column', 'P4 Row', 'P4 Column', 'Rows', 'Columns', 'Symbol Contrast', 'Symbol

Contrast SNR', 'Horizontal Mark Growth', 'Vertical Mark Growth', 'Data Matrix Cell Width', 'Data Matrix Cell

Height', 'Horizontal Mark Misplacement', 'Vertical Mark Misplacement ', 'Cell Defects', 'Finder Pattern Defects',

'Unused Error Correction'.





Related Products:
  • XTMZ40B

    XTMZ40B

    Automate Reader

    0.00

    0.00

  • XT8001E Android 13 PDA with 4.2'' screen

    XT8001E Android 13 PDA with 4.2'' screen

    PDA & Tablet PC & Cash Register

    0.00

    0.00

  • XTS03-2 Networked Barcode Error-Proofing System

    XTS03-2 Networked Barcode Error-Proofing System

    Automate Reader

    0.00

    0.00

  • XTS03-1 Barcode Verification & Poka-Yoke System

    XTS03-1 Barcode Verification & Poka-Yoke System

    Automate Reader

    0.00

    0.00

  • XT8501B MES WMS ERP System Integration Barcode Reader

    XT8501B MES WMS ERP System Integration Barcode Reader

    Data Matrix Scanner

    0.00

    0.00

  • XT8601B Barcode Scanner for Automation Factory

    XT8601B Barcode Scanner for Automation Factory

    Data Matrix Scanner

    0.00

    0.00

更多